Super Quality Certificated Parts Flow Control Valve Hydraulic Surge Anticipating Valve Flow Control Valve

Product Details
Customization: Available
Temperature: Ordinary Temperature
Certification: GS, CE, ISO9001
Gold Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
66
Year of Establishment
2009-01-12
  • Super Quality Certificated Parts Flow Control Valve Hydraulic Surge Anticipating Valve Flow Control Valve
  • Super Quality Certificated Parts Flow Control Valve Hydraulic Surge Anticipating Valve Flow Control Valve
  • Super Quality Certificated Parts Flow Control Valve Hydraulic Surge Anticipating Valve Flow Control Valve
  • Super Quality Certificated Parts Flow Control Valve Hydraulic Surge Anticipating Valve Flow Control Valve
  • Super Quality Certificated Parts Flow Control Valve Hydraulic Surge Anticipating Valve Flow Control Valve
  • Super Quality Certificated Parts Flow Control Valve Hydraulic Surge Anticipating Valve Flow Control Valve
Find Similar Products

Basic Info.

Standard
Standard
Connection Mode
Flange
Power
Hydraulic
Material
Alloy
Type
Sleeve
Size
DN50~DN600
Transport Package
Wooden Case
Specification
DN50~DN600
Trademark
HUIZHENG
Origin
China
HS Code
8481804090
Production Capacity
3000

Product Description


Super Quality Certificated Parts Flow Control Valve Hydraulic Surge Anticipating Valve Flow Control Valve
01.Description
Surge Anticipating Valve is indispensable for protecting pumps, pumping equipment and all applicable pipelines from dangerous pressure surges caused by rapid changes of flow velocity within a pipeline. When a power failure take place, the abrupt stopping the pump can cause dangerous surges in the system which could result in severe equipment damage. Power failure to a pump will usually result in a down surge in pressure, followed by an up surge in pressure. The surge control valve opens on the initial low pressure wave, diverting the returning high pressure wave from the system. In effect, the valve has anticipated the returning high pressure wave and is open to dissipate the damage causing surge. The valve will then close slowly without generating any shock.
02.Main parts&material
No. Part Material China stardard
1 body Ductile iron EN-JS1040
2 Seat ring Stainless steel AISI 304
3 O-ring Rubber NBR
4 O-ring Rubber NBR
5 Screw bolt Stainless steel A2
6 Gasket Stainless steel A2
7 bonnet Ductile iron EN-JS1040
8 Shaft Sleeve Lead Brass CZ 122
9 Spring Stainless steel AISI 304
10 Nut Stainless steel A2
11 Diaphragm Rubber NBR
12 Diaphragm pressure plate Ductile iron EN-JS1040
13 Hinge Pin Stainless steel AISI 304
14 Yoke Ductile iron EN-JS1040
15 Seal Ring Rubber NBR
16 Guide plate Stainless steel AISI 304
17 Stem Stainless steel AISI 304
I8 Plug Stainless steel AISI 304

03.Features
001.The diaphragm assembly provides long life and reliability with a stem guided by both top and seat rings.
002.All cast iron parts are coated with split epoxy resin to resist corrosion.
003.During maintenance, the main valve does not need to be removed from the pipeline and can be repaired directly on line.
004.The alignment of valve body allows for better control characteristics and lower head loss.
005.Ductile iron body has high strength and light weight.
006.Reinforced nylon diaphragm, film thickness uniform high strength, good precision, durable.
007.Internal use of stainless steel seat, guide platen and shaft, durable.
008.Good closing effect, zero leakage safety.
009.Hydraulic operation does not need external power, can cooperate with the need to match different guide valves and accessories as opening and closing or adjust the water level, pressure and flow.

04.Dimensions
DN  L B H D PN10 PN16 PN25 N.W. kg
50 230 173 232 85   4-019   14
65 290 197 259 95 4-019 4-019 8-019 19
80 310 224 279 102 8-019 8-019 8-019 23
100 350 265 305 120 8-019 8-019 8-023 32
150 480 352 445 152 8-023 8-023 8-028 68
200 600 436 569 182 8-023 12-023 12-028 112
250 730 518 611 212 12-023 12-028 12-031 178
300 850 600 659 242 12-023 12-028 16-031 225
DN L ØD ØK   H N-Ød
PN10 PN16 PN25 PN10 PN16 PN25 PN10 PN16 PN25
400 1100 565 580 620 515 525 550 813 16-028 16-031 16-037
450 1100 615 640 670 565 585 600 813 20-028 20-031 20-037
5CO 1250 670 715 730 620 650 660 967 20-028 20-034 20-037
6CO 1450 780 840 845 725 770 770 1140 20-031 20-037 20-040
700 1450 895 910 960 840 840 875 1140 24-031 24-037 24-043

05.Execution standard
Design standard CJ/T219, JB/T10674
Connection standard GB/T17241.6
Face spacing standard GB/T12221
Inspection testing standard GB/T13927

06.Technical parameters
Nominal diameter DN50~DN600(2"~24") PN10
DN50~DN600(2"~24") PN16
DN50~DN200(2"~8") PN25
Nominal pressure 0.1MPa-0.8MPa
0.8MPa-1.3MPa
1.3MPa-2.0MPa
Operating temperature -10°C~85°C
Seal test 1.1PN
Shell test 1.5PN
Suitable medium Water

07.Operating principle
Fluctuations when the pipeline pressure in normal circumstances, sampling valve tube after Y type filter to wave the upper valve diaphragm, a buffer holes due to the lower part of the diaphragm valve and valve body are interlinked, diaphragm valve at this time due to the fluctuation of pressure equal to there is no pressure difference and fluctuation valve close on lower part of the diaphragm spring force, when the sudden rise in pressure in pipe, rises high, lower part of high pressure pilot valve diaphragm pressure lifts suddenly, when the pressure rises to more than low pressure pilot valve spring pressure, high pressure pilot valve to open, will wave valve diaphragm upper water leakage, pressure fluctuation after the upper valve diaphragm pressure relief to the diaphragm valve spring force to overcome fluctuations, fluctuation valve open, high pressure pilot valve opens,Pressure water relief into the low-pressure guide valve, the low-pressure guide valve due to the spring force will open the low-pressure guide valve, further drain the pressure fluctuation valve diaphragm on the cavity of the water, so that the pressure fluctuation valve as soon as possible to open.When the water pressure in the pipeline falls, the water in the lower part of the high-pressure guide valve diaphragm is not enough to overcome the spring force on the low-pressure guide valve, the high-pressure guide valve closes, the low-pressure guide valve also closes, at this time the upper part of the fluctuation valve diaphragm is full of water, there is no pressure difference on the lower part of the fluctuation valve diaphragm, the fluctuation valve closes the fluctuation valve by the action of the spring force.Since the lower chamber is connected to the pressure in the valve body through a fixed hole, the closing of the valve is cushioned.

ABOUT US:
Super Quality Certificated Parts Flow Control Valve Hydraulic Surge Anticipating Valve Flow Control Valve
Super Quality Certificated Parts Flow Control Valve Hydraulic Surge Anticipating Valve Flow Control Valve

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier